legislation-obligation

Substance Regulatory Obligations

OBL

Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans

EC number: -

CAS number: -

Last updated: 25/05/2022
ECHA Legislation Regulatory Obligations

Regulatory obligations may exist for this substance under the legislations under ECHA’s remit or for which ECHA has delegated tasks (i.e. REACH, CLP, BPR, PIC, CAD / CMD, WFD, and POPs). Please check the substance Infocard.

Industrial Emissions Directive

IPPC - Industrial Emissions Directive, Annex II - Polluting Substances

This list contains the polluting substances for which emission limit values are assigned under Directive 2010/75/EU on Industrial Emissions (Integrated Pollution Prevention and Control - IPPC). Member States must permit all qualifying facilities in order to ensure that they minimize impact on the environment. The permit issued must provide emission limit values for pollutants on this list.

Name CAS Air Water Annex X of Dir 2000/60/EC
Polychlorinated dibenzodioxins and polychlorinated dibenzofurans
yes

IPPC, Annexes V, VI, VIII - Provisions relating to industrial plants

This list contains emission limit values for polluting substances in waste gases and waste water, assigned according to facility type (i.e., combustion plants (Annex V), waste incineration/co-incineration plants (Annex VI), and installations producing titanium dioxide (Annex VIII)), under Directive 2010/75/EU on Industrial Emissions (Integrated Pollution Prevention and Control - IPPC). For this list, if a substance presents 2 values in the ''Average sampling duration'' field, these indicate minimum and maximum average sampling period.

Name CAS Expressed As Annex Group Average duration qualifier Average limit Maximum limit Average sampling duration Emission medium fuel Fuel class Part Point Thermal input Process/equipment Qualifier Notes  
Dioxins and furans
VI Annex VI (Directive 2010/75/EU) Technical provisions relating to waste incineration plants and waste co-incineration plants
Dioxins and furans
0.3 ng/l
Waste water from the cleaning of waste gases
Part 5 (VI) Emission limit values for discharges of waste water from the cleaning of waste gases
Waste incineration plants and waste co-incineration plants
Details
Dioxins and furans
VI Annex VI (Directive 2010/75/EU) Technical provisions relating to waste incineration plants and waste co-incineration plants
Dioxins and furans
0.1 ng/nm3
8 h
6 h
Waste gases
Part 3 (VI) Air emission limit values for waste incineration plants
1.4
Waste incineration plants
21 All emission limit values shall be calculated at a temperature of 273,15 K, a pressure of 101,3 kPa and after correcting for the water vapour content of the waste gases.They are standardised at 11 % oxygen in waste gas except in case of incineration of mineral waste oil as defined in point 3 of Article 3 of Directive 2008/98/EC, when they are standardised at 3 % oxygen, and in the cases referred to in Point 2.7 of Part 6
25 'Dioxins and furans' means all polychlorinated dibenzo-p-dioxins and dibenzofurans listed in Part 2 of Annex VI. For the determination of the total concentration of dioxins and furans, the mass concentrations of the dibenzo-p-dioxins and dibenzofurans shall be multiplied by the equivalence factors before summing
35 Emission limit value defined as total emission limit for the total sum of dioxins and furans, expressed as average value over the sampling period
39 For technical provisions regarding 'Monitoring of emissions' see Part 6 (Annex VI). For 'Formula to calculate the emission concentration at the standard percentage oxygen concentration' see Part 7 (Annex VI). For 'Assessment of compliance with emission limit values' see Part 8 (Annex VI) Directive 2010/75/EU
Details
Dioxins and furans
VI Annex VI (Directive 2010/75/EU) Technical provisions relating to waste incineration plants and waste co-incineration plants
Dioxins and furans
0.1 ng/nm3
8 h
6 h
Waste gases
Part 4 (VI) Determination of air emission limit values for the co-incineration of waste
2.2
Cement kilns co-incinerating waste
25 'Dioxins and furans' means all polychlorinated dibenzo-p-dioxins and dibenzofurans listed in Part 2 of Annex VI. For the determination of the total concentration of dioxins and furans, the mass concentrations of the dibenzo-p-dioxins and dibenzofurans shall be multiplied by the equivalence factors before summing
28 All values are standardised at 10 % oxygen
30 All emission limit values shall be calculated at a temperature of 273,15 K, a pressure of 101,3 kPa and after correcting for the water vapour content of the waste gases
35 Emission limit value defined as total emission limit for the total sum of dioxins and furans, expressed as average value over the sampling period
39 For technical provisions regarding 'Monitoring of emissions' see Part 6 (Annex VI). For 'Formula to calculate the emission concentration at the standard percentage oxygen concentration' see Part 7 (Annex VI). For 'Assessment of compliance with emission limit values' see Part 8 (Annex VI) Directive 2010/75/EU
Details
Dioxins and furans
VI Annex VI (Directive 2010/75/EU) Technical provisions relating to waste incineration plants and waste co-incineration plants
Dioxins and furans
0.1 ng/nm3
8 h
6 h
Waste gases
Solid or liquid
Part 4 (VI) Determination of air emission limit values for the co-incineration of waste
3.4
Combustion plants co-incinerating waste
25 'Dioxins and furans' means all polychlorinated dibenzo-p-dioxins and dibenzofurans listed in Part 2 of Annex VI. For the determination of the total concentration of dioxins and furans, the mass concentrations of the dibenzo-p-dioxins and dibenzofurans shall be multiplied by the equivalence factors before summing
30 All emission limit values shall be calculated at a temperature of 273,15 K, a pressure of 101,3 kPa and after correcting for the water vapour content of the waste gases
34 O2 content 6% for solid fuels and 3% for liquid fuels
35 Emission limit value defined as total emission limit for the total sum of dioxins and furans, expressed as average value over the sampling period
39 For technical provisions regarding 'Monitoring of emissions' see Part 6 (Annex VI). For 'Formula to calculate the emission concentration at the standard percentage oxygen concentration' see Part 7 (Annex VI). For 'Assessment of compliance with emission limit values' see Part 8 (Annex VI) Directive 2010/75/EU
Details
Dioxins and furans
VI Annex VI (Directive 2010/75/EU) Technical provisions relating to waste incineration plants and waste co-incineration plants
Dioxins and furans
0.1 ng/nm3
8 h
6 h
Waste gases
Part 4 (VI) Determination of air emission limit values for the co-incineration of waste
4.1
Combustion plants co-incinerating waste
For waste co-incineration plants in industrial sectors not covered under Points 2 and 3 of this Part (Annex VI, Part 4)
25 'Dioxins and furans' means all polychlorinated dibenzo-p-dioxins and dibenzofurans listed in Part 2 of Annex VI. For the determination of the total concentration of dioxins and furans, the mass concentrations of the dibenzo-p-dioxins and dibenzofurans shall be multiplied by the equivalence factors before summing
30 All emission limit values shall be calculated at a temperature of 273,15 K, a pressure of 101,3 kPa and after correcting for the water vapour content of the waste gases
35 Emission limit value defined as total emission limit for the total sum of dioxins and furans, expressed as average value over the sampling period
39 For technical provisions regarding 'Monitoring of emissions' see Part 6 (Annex VI). For 'Formula to calculate the emission concentration at the standard percentage oxygen concentration' see Part 7 (Annex VI). For 'Assessment of compliance with emission limit values' see Part 8 (Annex VI) Directive 2010/75/EU