Regulatory obligations may exist for this substance under the legislations under ECHA’s remit or for which ECHA has delegated tasks (i.e. REACH, CLP, BPR, PIC, CAD / CMD, WFD, and POPs). Please check the substance Infocard.

Urban Waste Water Treatment Directive

Urban Waste Water Treatment Directive, Annex I: Discharge requirements

This list contains requirements for (1) discharges from urban waste water treatment plants (Annex I, Table 1), and (2) discharges to sensitive areas (Annex I, Table 2), under Directive 91/271/EEC.

Name Concentration Expressed As Method Minimum reduction Qualifier Table Parametri Notes  
Total nitrogen
15 mg/l
Molecular absorption spectrophotometry
70 %
80 %
10000 - 100000 p.e.
2
3 Total nitrogen means the sum of total Kjeldahl nitrogen (organic and ammoniacal nitrogen) nitrate-nitrogen and nitrite-nitrogen.
4 These values for concentration are annual means as referred to in Annex I, paragraph D.4(c). However, the requirements for nitrogen may be checked using daily averages when it is proved, in accordance with Annex I, paragraph D.1, that the same level of protection is obtained. In this case, the daily average must not exceed 20 mg/l of total nitrogen for all the samples when the temperature from the effluent in the biological reactor is superior or equal to 12 °C. The conditions concerning temperature could be replaced by a limitation on the time of operation to take account of regional climatic conditions.
Details
Total nitrogen
10 mg/l
Molecular absorption spectrophotometry
70 %
80 %
more than 100000 p.e.
2
3 Total nitrogen means the sum of total Kjeldahl nitrogen (organic and ammoniacal nitrogen) nitrate-nitrogen and nitrite-nitrogen.
4 These values for concentration are annual means as referred to in Annex I, paragraph D.4(c). However, the requirements for nitrogen may be checked using daily averages when it is proved, in accordance with Annex I, paragraph D.1, that the same level of protection is obtained. In this case, the daily average must not exceed 20 mg/l of total nitrogen for all the samples when the temperature from the effluent in the biological reactor is superior or equal to 12 °C. The conditions concerning temperature could be replaced by a limitation on the time of operation to take account of regional climatic conditions.
Details