21 All emission limit values shall be calculated at a temperature of 273,15 K, a pressure of 101,3 kPa and after correcting for the water vapour content of the waste gases.They are standardised at 11 % oxygen in waste gas except in case of incineration of mineral waste oil as defined in point 3 of Article 3 of Directive 2008/98/EC, when they are standardised at 3 % oxygen, and in the cases referred to in Point 2.7 of Part 6
22 These average values cover also the gaseous and the vapour forms of the relevant heavy metal emissions as well as their compounds
24 Emission limit value defined as total emission limit for the total sum of antimony, arsenic, lead, chromium, cobalt, copper, manganese, nickel and vanadium, expressed as average value over the sampling period
39 For technical provisions regarding 'Monitoring of emissions' see Part 6 (Annex VI). For 'Formula to calculate the emission concentration at the standard percentage oxygen concentration' see Part 7 (Annex VI). For 'Assessment of compliance with emission limit values' see Part 8 (Annex VI) Directive 2010/75/EU
|