Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes
Type of method:
static method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: crystalline

Results and discussion

Vapour pressure
Temp.:
20 °C
Vapour pressure:
< 75 Pa
Remarks on result:
other: Sample couldn't be degassed satisfactorily. VP most likely due to trapped volatiles.

Applicant's summary and conclusion

Conclusions:
Vapour pressure < 75 Pa at 20 degrees C. Sample couldn't be degassed satisfactorily. VP most likely due to trapped volatiles.
Executive summary:

Vapour pressure <75 Pa at 20 degrees C. Sample couldn't be degassed satisfactorily. VP most likely due to trapped volatiles.