Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
other:
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
According to REACh Annex XI / section 2, flammability study UN N1 relevant for classification criteria under IUCLID Section 4.13 does not apply to liquids. Please refer to Flash Point under IUCLID section 4.11.
Reason / purpose for cross-reference:
reference to other study

Description of key information




According to REACH Regulation (EC) 1907/2006 Annex XI, the flammability is deduced from flash point (115°C, literature; see IUCLID section 4.11).




Key value for chemical safety assessment

Flammability:
non flammable

Additional information

A waiver is proposed for this endpoint. Moreover, the substance has a long history of use as a flame retardant and can therefore justifiably be considered to be non-flammable.

Justification for classification or non-classification




According to Regulation (EC) No.1272/2008 (CLP) criteria, the measured flash point is above the threshold values of 60°C, therefore the substance is NOT considered as a flammable liquid.