Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1999
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study performed on commercial product not under glps.

Data source

Referenceopen allclose all

Reference Type:
other company data
Title:
Unnamed
Year:
1999
Reference Type:
publication
Title:
Unnamed
Year:
2002

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Performed in-house by Albemarle on the commercial DecaBDE product.
GLP compliance:
no
Type of method:
other: Differential Scanning Calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Melting / freezing point
Melting / freezing pt.:
304 °C
Remarks on result:
other: Measurement performed at sea level and room temperature.

Applicant's summary and conclusion