Registration Dossier

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Peer-reviewed DIPPR database data
Principles of method if other than guideline:
Method not mentioned in literature reference.
Type of method:
other: literature does not mention method
Temp.:
other: 298.15K
Parameter:
dynamic viscosity (in mPa s)
Value:
1.073
Remarks on result:
other: experimental/predicted

The purity of the tested sample is not known, but it can be assumed the test was run with a commercially available sample (>99.5% purity).

Conclusions:
The viscosity of pure Epichlorohydrin has been determined at 20°C as 1.037 mPa.s (dynamic).

Description of key information

The viscosity is 1.037 mPa.s at 298.15 K. 

Key value for chemical safety assessment

Viscosity:
1.037 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information