Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The study is regarded as reliable with restrictions because study report is not available but data seem comprehensive and scientifically acceptable.

Data source

Reference
Reference Type:
other: ECHA disseminated dossier
Title:
Flash point
Author:
Anonymus
Year:
2012
Bibliographic source:
ECHA Homepage
Report Date:
2014

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
not specified
Type of method:
non-equilibrium method closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: liquid

Results and discussion

Flash point
Flash point:
> 100 °C

Any other information on results incl. tables

No flash point of the test item was detected up to 100°C, after that test item was vaporized and determination > 100 °C was not possible.