Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Particles size after sieving < 400 µm:

MMD= 12 µm

D10= 4.8 µm

D90= 21 µm

Additional information

The determination was conducted following the principle of static light scattering,

Since the applied method is not suitable for bulk solids having a too wide particle size distribution, the sample was sieved with a 400 micron sieve to eliminate about 26% of coarse particles in order to better focus on the fine particles < 400 micron.