Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: scientifically acceptable
Guideline:
other: measured
Principles of method if other than guideline:
Method: vapour pressure curve
GLP compliance:
no
Type of method:
dynamic method
Temp.:
30.6 °C
Vapour pressure:
2.01 hPa
Temp.:
61.9 °C
Vapour pressure:
15.5 hPa
Temp.:
89.2 °C
Vapour pressure:
65.1 hPa
Temp.:
130.8 °C
Vapour pressure:
386.5 hPa
Temp.:
159.3 °C
Vapour pressure:
1 013 hPa

Temperature, ° C / pressure, hPa:
30.6/2.01;

46.6/5.93;

61.9/15.5;

69.9/24.3;

89.2/65.1;
108.9/160.1;

130.8/386.5;

151.8/798.5;

159.3/1013

Conclusions:
VP = 2.01 hPa at 30.6°C
Executive summary:

Vapour pressure was determined experimentally by dynamic method. Measurements were performed at 9 temperature levels and a vapour pressure curve was plotted.Temperature, ° C / pressure, hPa: 30.6/2.01; 46.6/5.93; 61.9/15.5; 69.9/24.3; 89.2/65.1; 108.9/160.1; 130.8/386.5; 151.8/798.5; 159.3/1013.

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Peer reviewed database
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Principles of method if other than guideline:
experimental determination
GLP compliance:
not specified
Type of method:
other: experimental determination
Temp.:
20 °C
Vapour pressure:
1 mBar
Temp.:
64 °C
Vapour pressure:
16 mBar
Conclusions:
VP = 1 mbar at 20°C,
VP = 16 mbar at 64°C
Executive summary:

VP = 1 mbar at 20°C,

VP = 16 mbar at 64°C

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Peer reviewed database
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Principles of method if other than guideline:
experimental determination
GLP compliance:
not specified
Type of method:
other: experimental determination
Temp.:
25 °C
Vapour pressure:
1.08 mm Hg
Conclusions:
VP = 1.08 mm Hg at 25°C
Executive summary:

VP = 1.08 mm Hg at 25°C

Description of key information

Vapour pressure: 2.01 hPa at 30.6°C (measured)

Key value for chemical safety assessment

Vapour pressure:
2.01 hPa
at the temperature of:
30.6 °C

Additional information

The vapour pressure was experimentally determined by a dynamic method (BASF, 1972). Nine different temperature levels were used in this test (~ 30°C - ~ 160 °C).