Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
according to guideline
Guideline:
ISO No., other: German standard DIN 51 758
Principles of method if other than guideline:
Flash point was determined experimentally according to German standard DIN 51758 (Penky-Martens principle).
GLP compliance:
no
Type of method:
other: according to Pensky-Martens
Flash point:
76 °C
Atm. press.:
1 013.25 hPa
Interpretation of results:
other: EU GHS criteria not met
Conclusions:
Flash point = 76°C.
Executive summary:

Flash point was determined experimentally according to German standard DIN 51758 (Penky-Martens principle).

Result: Flash point = 76°C.

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Peer reviewed database
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Principles of method if other than guideline:
experimental determination (open cup)
GLP compliance:
not specified
Type of method:
open cup
Remarks:
experimental determination
Flash point:
74 °C
Remarks on result:
other: No further experimental details given
Interpretation of results:
other: EU GHS criteria not met
Conclusions:
Flash point = 74°C
Executive summary:

Flash point = 74°C

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Peer reviewed database
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Principles of method if other than guideline:
experimental determination
GLP compliance:
not specified
Type of method:
other: experimental determination
Flash point:
73.9 °C
Remarks on result:
other: No further experimental details given
Interpretation of results:
other: EU GHS criteria not met
Conclusions:
Flash point = 73.9°C
Executive summary:

Flash point = 73.9°C

Description of key information

Flash point = 76°C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
76 °C

Additional information

The flash point was determined experimentally according to German standard DIN 51758 (Penky-Martens principle) by BASF AG (1968). The result is confirmed by available handbook data.