Registration Dossier

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report Date:
2009

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Principles of method if other than guideline:
Dynamic viscosity, measuring according ISO 3219:1993
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Details on test material:
Composite Sample No. 08
Smola S090 (REACH 31.1.08)
___________________________________________________________________________

Results and discussion

Viscosityopen allclose all
Temp.:
other: 140.0°C
Parameter:
dynamic viscosity (in mPa s)
Value:
ca. 9 230
Temp.:
other: 190.0°C
Parameter:
dynamic viscosity (in mPa s)
Value:
ca. 230

Applicant's summary and conclusion