Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 212-660-9 | CAS number: 839-90-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Dissociation constant
Administrative data
Link to relevant study record(s)
- Endpoint:
- dissociation constant
- Type of information:
- calculation (if not (Q)SAR)
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- accepted calculation method
- Qualifier:
- according to guideline
- Guideline:
- other: no guideline followed
- Version / remarks:
- see "Principles of method if other than guideline"
- Deviations:
- not applicable
- Principles of method if other than guideline:
- Since the test item does not contain any functional groups likely to dissociate under normal conditions, no experimental work was performed. Instead, calculation of the dissociation constant using ACD/Labs I-Lab 2.0 was performed.
ACD/pKa calculates accurate acid-base ionization constants (pKa values) for 25°C and zero ionic strength in aqueous solutions. Each calculation is provided with its 95% confidence limits. The accuracy of calculations is usually better than ±0.2 pKa units (for very complex structures, better than ±0.5 pKa units). - GLP compliance:
- yes
- Dissociating properties:
- no
- Conclusions:
- The hydroxy groups of the test material will not dissociate under normal environmental conditions as the pKa values are not within the environmentally relevant pH range of 5-9 (see REACH Guidance on information requirements and chemical safety assessment, chapter R.7.1.17).
Reference
The predicted pKa values were in the range of 14.03 – 14.99 (95% confidence limits ± 0.1) for the hydroxyl groups and -3.74 – -2.59 (95% confidence limits ± 0.2) for the amine groups.
For details see attached document "pKa results from computer prediction.pdf".
Description of key information
The test item does not contain any functional groups which are likely to dissociate under normal conditions.
Key value for chemical safety assessment
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.