Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP compliant guideline study, available as unpublished report, no restrictions, fully adequate for assessment.
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
GLP compliance:
yes
Analytical monitoring:
no
Vehicle:
no
Details on test solutions:
An initial loading rate of 200 mg/L was stirred fir a period of at least 24 hours in a closed test bottle. Subsequently, synthetic sewage feed and sludge were added resulting in a final loading of 100 mg/L.
Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
Sludge originated from the municipal sewage treatment plant "Waterschap de Maaskant in Den Bosch, the Netherlands".

Upon retrieval the sludge was coarsely sieved and diluted with ISO-medium. The amount of suspended solids was 3.9 g/L.
Test type:
static
Water media type:
freshwater
Limit test:
yes
Total exposure duration:
3 h
Test temperature:
18.1 to 18.9 ºC
pH:
8.6
Nominal and measured concentrations:
Nominal: 100 mg/L
Details on test conditions:
TEST SYSTEM
- Type (delete if not applicable): closed
- Material, size, headspace, fill volume: glass, 1 L
- Aeration: yes
- No. of vessels per concentration (replicates): 2
- No. of vessels per control (replicates): 2
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol
Key result
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 100 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Details on results:
- Effect concentrations exceeding solubility of substance in test medium: yes
Results with reference substance (positive control):
- Results with reference substance valid? yes
- Relevant effect levels: 20.1 mg/L
Validity criteria fulfilled:
yes
Conclusions:
The 3-h EC50 value of AC-6000 in domestic activated sludge is >100 mg/L.
Executive summary:

In a GLP-compliant OECD 209 guideline study for AC-6000with predominantly domestic sludge, activated sludge (0.7 g/L suspended solids, 2 replicates) was exposed to a nominal concentration of 100 mg/L for 3 hours.




The test concentration was prepared by stirring the test solution with a target dose level of 200 mg/L for 24 hours before exposure. The growth inhibition rate of the test substance was 9%. The 3-h EC50 value is >100 mg/L, this effect concentration is larger than the water solubility.

Description of key information

The 3-h EC50 value of AC-6000 in domestic activated sludge is >100 mg/L; this value will be used in the assessment.

Key value for chemical safety assessment

EC50 for microorganisms:
100 mg/L

Additional information

A GLP-compliant OECD 209 guideline study with predominantly domestic sludge is available for AC-6000 (NOTOX B.V., 2007). Activated sludge (0.7 g/L suspended solids, 2 replicates) was exposed to a nominal concentration of 100 mg/L for 3 hours.

The test concentration was prepared by stirring the test solution with a target dose level of 200 mg/L for 24 hours before exposure. The growth inhibition rate of the test substance was 9%. The 3-h EC50 value is >100 mg/L, this effect concentration is larger than the water solubility.