Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP compliant guideline study, available as unpublished report, no restrictions, fully adequate for assessment.
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
yes (incl. QA statement)
Key result
Auto-ignition temperature:
400 °C
Atm. press.:
1 003.8 - 1 018 hPa
Remarks on result:
other:
Conclusions:
The test substance is auto-ignitable with an auto-ignition temperature of 400 °C at 1003.8-1018.0 hPa.
Executive summary:

A commercially available auto-ignition temperature apparatus (Chilworth Technology, Southampton, UK) was used to determine the degree of auto-ignitability. The test substance is auto-ignitable with an auto-ignition temperature of 400 °C at 1003.8-1018.0 hPa.

Description of key information

A commercially available auto-ignition temperature apparatus (Chilworth Technology, Southampton, UK) was used to determine the degree of auto-ignitability. The test substance is auto-ignitable with an auto-ignition temperature of 400 °C at 1003.8-1018.0 hPa.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
400 °C

Additional information

Data from a GLP-compliant guideline study, fully adequate for assessment.