Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Experimental value of flash point at 98.3kPa:  no flash point was observed up to 120.0 °C(corrected value)

Key value for chemical safety assessment

Additional information

The flash point was determined using equilibrium method closed cup according to Method A.9 "Flash-Point" of Commission Regulation N°440/2008 of 30 May 2008, ISO Standard 3679 "Determination of flash point - Rapid equilibrium closed cup method" of 2004 and GLP. No deviation from the guideline was observed.

At 120.0 °C, the test item boiled and overflowed of the small dish just before the presentation of the flame. So the conclusion of the test is that: no flash point was observed up to 120.0 °C (corrected value).