Physical & Chemical properties

Oxidising properties

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
oxidising solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
oxidising liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because there are no chemical groups present in the molecule which are associated with oxidising properties and hence, the classification procedure does not need to be applied
Endpoint:
oxidising gases
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid

Description of key information

The test item has not to be classified as oxidising solid, oxidising liquid or oxidising gas.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Oxidising gases


The test item is a liquid at ambient conditions. This hazard class is only applicable for gases. Thus, the substance was not considered for classification as oxidising gases.


 


Oxidising liquids


According the screening procedures as described in Appendix 6 of the Manual of Tests and Criteria seventh revised edition United Nations 2019 for organic compounds, the classification procedure for oxidising substances of Division 5.1 need not to be applied if:


(a) The compound does not contain oxygen, fluorine or chlorine; or


(b) The compound contains oxygen, fluorine or chlorine and these elements are chemically bonded only to carbon or hydrogen.


As the test item contains oxygen chemically bonded only to carbon and hydrogen the classification procedure does not need to be applied.


 


Oxidising solids


The test item is a liquid at ambient conditions. This hazard class is only applicable for solids. Thus, the substance was not considered for classification as oxidising solid.

Justification for classification or non-classification



Classification, Labelling, and Packaging Regulation (EC) No 1272/2008


Based on the chemical structure and taking into account the provisions laid down in Regulation (EC) No 1272/2008 (CLP), as amended for the fifteenth time in Regulation (EU) 2020/1182, and UN GHS Rev 8 (2019) the substance is not considered to be classified for oxidising properties.