EC number: 201-898-9 | CAS number: 89-32-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Adsorption / desorption
Administrative data
Link to relevant study record(s)
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- September 15 - January 2016
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC estimation method
- Media:
- other: LiChrospher CN 100A 250 × 4.6 mm, 5µm
- Specific details on test material used for the study:
- - Batch number: NJC1506009
- Appearance: White crystals
- Manufacturing date: 11 June 2015
- Expiry date: 10 December 2016
- Storage conditions: Controlled room temperature (15-25°C, below 70 RH%), under inert gas, protected from humidity
- Safety precautions: Routine safety precautions (lab coat, gloves, safety glasses, face mask) for unknown materials were applied to assure personnel health and safety. - Radiolabelling:
- no
- Test temperature:
- Room temperature
- Details on study design: HPLC method:
- HPLC-SYSTEM & CONDITIONS:
-Merck-Hitachi LaChrom HPLC system:
D-7000 Interface
L-7100 HPLC pump
L-7200 Autosampler
L-7400 UV Detector
L-7612 Degasser
655A-52 Column thermostat
- Balance: BP221S Sartorius
- Ultrasonic bath: Elmasonic S300H, ELMA
- Water purification system: MILLIPORE, DIRECT Q8 UV
- Detector: UV at 220 and 254 nm
- Column: LiChrospher CN 100A 250 × 4.6 mm, 5µm
- Mobile Phase: Acetonitrile: ultrapure water = 6 : 4
- Flow: 1 ml/min.
- Injection volume: 10 ul
- Temperature: 25 °C
REFERENCE SUBSTANCES:
Six chemicals for which log Koc has been reported were used to calibrate the elution time in units of log Koc. Dead time, t0 was determined by the injection of sodium nitrate solution.
Chemical name CAS Number log Koc Purity % Batch No.
Sodium nitrate 7631-99-4 t0 100.8 PP/2011/09731
Acetanilide 103-84-4 1.25 99.9 S6921344
Methyl benzoate 93-58-3 1.80 99.7 S6046630
Triazophos 24017-47-8 2.55 98.9 SZBD102XY
Naphthalene 91-20-3 2.75 99.9 S6258846
Fenthion 55-38-9 3.31 96.2 SZBB010XV
alpha-Endosulfan 959-98-8 4.09 99.6 SZB8289XV
PREPARATION OF TEST SOLUTIONS:
Reference substances were dissolved in acetonitrile. Concentration of these stock solutions was about 1 mg/ml. These stock solutions were diluted with eluent resulting in about 10 µg/ml solutions. In case of Sodim Nitrate the 1 mg/ml solution was prepared. Test item was dissolved in acetonitrile. The concentration of this solution was about 1 mg/ml. This stock solution was diluted with eluent resulting in 10 mg/ml solution.
DETERMINATION OF RETENTION TIMES:
Three series of the above reference solutions and the test item solution were measured alternately, with two replicate injections. For the determination of t0 (t0 = retention time of the unretarded component) sodium nitrate solution was injected. The retention times were determined. - Key result
- Sample No.:
- #1
- Type:
- log Koc
- Value:
- < 0.155 dimensionless
- Temp.:
- 25 °C
- Matrix:
- HPLC-column
- Key result
- Sample No.:
- #1
- Type:
- Koc
- Value:
- < 1 dimensionless
- Temp.:
- 25 °C
- Matrix:
- HPLC-column
- Details on results (HPLC method):
- The test item elutes with retention time of 1.41 minutes, before the first reference item having log Koc and Koc, so the calibration cannot be apply. Therefore the log Koc and Koc are lower than 0.155 and 1.00 (the logKoc and Koc of the first reference item).
- Validity criteria fulfilled:
- yes
- Conclusions:
- The test item elutes with retention time of 1.41 minutes, before the first reference item having log Koc and Koc, so the calibration cannot be apply. Therefore the log Koc and Koc are lower than 0.155 and 1.00 (the logKoc and Koc of the first reference item).
- Executive summary:
The test item was investigated for its adsorption/desorption behaviour in a screening test, in accordance with EC-method C.19 (HPLC-method). The test item elutes with retention time of 1.41 minutes, before the first reference item having log Koc and Koc, so the calibration cannot be apply. Therefore the log Koc and Koc are lower than 0.155 and 1.00 (the logKoc and Koc of the first reference item).
Reference
Description of key information
The test item was investigated for its adsorption/desorption behaviour in a screening test, in accordance with EC-method C.19 (HPLC-method). The test item elutes with retention time of 1.41 minutes, before the first reference item having log Koc and Koc, so the calibration cannot be apply. Therefore the log Koc and Koc are lower than 0.155 and 1.00 (the logKoc and Koc of the first reference item).
Key value for chemical safety assessment
- Koc at 20 °C:
- 1
Additional information
Source: GLP-report
[LogKoc: 0.155]
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.