Endpoint:
acute toxicity: inhalation
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because exposure of humans via inhalation is not likely taking into account the vapour pressure of the substance and/or the possibility of exposure to aerosols, particles or droplets of an inhalable size
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
The content of inhalable particles in the the registered substance is very low. The particle size distribution of the test item was found to be [125 μm; 1000 μm]. Less than 10% of the test item is larger than 1 mm and more than 90% is larger than 125 μm.