Registration Dossier

Administrative data

Endpoint:
thermal stability
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report Date:
1999

Materials and methods

Test guideline
Qualifier:
equivalent or similar to
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid
Details on test material:
Test material: Phthalide
Purity: pure (not specified)

Results and discussion

For thermal stability study

Test substance thermally stable:
yes
Operating temperature
Key result
Operating temp.:
30 - 400 °C
Remarks on result:
other: exothemic reaction: 40 J/g at onset temperatue 200 °C

Any other information on results incl. tables

Results

1.Reaction

 

Onset-temperature

200 °C

Peak temperature       

254 °C

Energy release

40 J/g

Applicant's summary and conclusion