Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study performed under well-known test procedure
Qualifier:
no guideline required
Principles of method if other than guideline:
The particle size analysis was done by laser diffraction
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Remarks on result:
other: See table below
Key result
Percentile:
D10
Mean:
30 µm
Remarks on result:
other: no data available
Key result
Percentile:
D50
Mean:
101 µm
Remarks on result:
other: no data available
Key result
Percentile:
D90
Mean:
248 µm
Remarks on result:
other: no data available
Remarks on result:
other: n.a.
Conclusions:
The particle size analysis was done by laser diffraction and gave a D(0,5) of 101µm

Description of key information

The particle size analysis was done by laser diffraction and gave a D(0,5) of 101µm

Additional information