Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Oct 2009
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test done according to A.10 guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Parameter:
lower explosion limit
Remarks on result:
other: not concerned
Parameter:
upper explosion limit
Remarks on result:
other: not concerned
Type of aerosol tested:
aerosol dispenser: not specified
Remarks:
or specified in description of method (migrated information)
Test parameter:
ignition distance (cm)
Remarks:
original parameter: flame extension (cm) (migrated information)
Remarks on result:
other: not concerned
Type of aerosol tested:
aerosol dispenser: not specified
Remarks:
or specified in description of method (migrated information)
Test parameter:
maximum flame height (cm)
Remarks:
original parameter: flame projection (cm) (migrated information)
Remarks on result:
other: not concerned
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: The product does not ignite, there is no propagation of the flame.
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record. | Remarks: | Additional remarks: Experience shows no ignition on contact with air
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record. | Remarks: | Additional remarks: Experience shows no ignition on contact with air

The product does not ignite, there is no propagation of the flame; thus is not a flammable solid.

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
Oxalic acid is a non flammable substance.

Description of key information

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Justification for classification or non-classification