Registration Dossier

Administrative data

First-aid measures

4.1. Description of first aid measures
Immediately remove contaminated clothing. If the patient is likely to become unconscious, place and
transport in stable sideways position (recovery position). If not breathing, give artificial respiration.
First aid personnel should pay attention to their own safety.
If inhaled:
Keep patient calm, remove to fresh air, seek medical attention. Immediately administer a
corticosteroid from a controlled/metered dose inhaler.
On skin contact:
Immediately wash thoroughly with plenty of water, apply sterile dressings, consult a skin specialist.
On contact with eyes:
Immediately wash affected eyes for at least 15 minutes under running water with eyelids held open,
consult an eye specialist.
On ingestion:
Immediately rinse mouth and then drink 200-300 ml of water, seek medical attention.
4.2. Most important symptoms and effects, both acute and delayed
Symptoms: Information, i.e. additional information on symptoms and effects may be included in the
GHS labeling phrases available in Section 2 and in the Toxicological assessments available in
Section 11., Further symptoms are possible
4.3. Indication of any immediate medical attention and special treatment needed
Treatment: Treat according to symptoms (decontamination, vital functions), no known specific
antidote. Pulmonary odema prophylaxis. Medical monitoring for at least 24 hours.

Fire-fighting measures

5.1. Extinguishing media
Suitable extinguishing media:
dry powder, carbon dioxide, water spray, alcohol-resistant foam
5.2. Special hazards arising from the substance or mixture
carbon monoxide, Carbon dioxide, nitrous gases
The substances/groups of substances mentioned can be released in case of fire. Vapours may form
explosive mixture with air. Pressure inside container is increased when heated, and may cause
explosion.
5.3. Advice for fire-fighters
Special protective equipment:
Wear self-contained breathing apparatus and chemical-protective clothing.
Further information:
Cool endangered containers with water-spray. Collect contaminated extinguishing water separately,
do not allow to reach sewage or effluent systems. Dispose of fire debris and contaminated
extinguishing water in accordance with official regulations.

Accidental release measures

6.1. Personal precautions, protective equipment and emergency procedures
Use personal protective clothing. Information regarding personal protective measures, see section 8.
Avoid all sources of ignition: heat, sparks, open flame. Ensure adequate ventilation. Avoid inhalation.
Wear respiratory protection if ventilation is inadequate. Avoid contact with the skin, eyes and
clothing.
6.2. Environmental precautions
Do not discharge into drains/surface waters/groundwater.

6.3. Methods and material for containment and cleaning up
For small amounts: Pick up with absorbent material (e.g. sand, sawdust, general-purpose binder).
For large amounts: Dike spillage. Pump off product. Cover with blanket of foam (alcohol-resistant
foam).
Avoid sources of ignition. Use spark-proof tools and explosion-proof equipment. Wear suitable
protective equipment. Cleaning operations should be carried out only while wearing breathing
apparatus. Clean contaminated floors and objects thoroughly with water and detergents, observing
environmental regulations. Collect waste in suitable containers, which can be labeled and sealed.
Incinerate or take to a special waste disposal site in accordance with local authority regulations.
6.4. Reference to other sections
Information regarding exposure controls/personal protection and disposal considerations can be
found in section 8 and 13.

Handling and storage

7.1. Precautions for safe handling
Ensure thorough ventilation of stores and work areas. Protect against moisture. Wear suitable
protective clothing and eye/face protection. Use only alkali-proof equipment.
Protection against fire and explosion:
The product is combustible. Vapours may form ignitable mixture with air. Prevent electrostatic charge
- sources of ignition should be kept well clear - fire extinguishers should be kept handy.
7.2. Conditions for safe storage, including any incompatibilities
Segregate from acids and acid forming substances. Segregate from strong oxidizing agents.
Suitable materials for containers: Carbon steel (Iron), Stainless steel 1.4301 (V2), Stainless steel
1.4541, Stainless steel 1.4401, Stainless steel 1.4571, Low density polyethylene (LDPE), High
density polyethylene (HDPE), glass
Further information on storage conditions: Avoid all sources of ignition: heat, sparks, open flame.
Keep container tightly closed in a cool, well-ventilated place.
Storage class according to TRGS 510 (originally VCI, Germany): (3) Flammable liquids
Storage stability:
Storage duration: 24 Months
From the data on storage duration in this safety data sheet no agreed statement regarding the
warrantee of application properties can be deduced.
7.3. Specific end use(s)
See exposure scenario(s) in the attachment to this safety data sheet.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

8.1. Control parameters
Components with occupational exposure limits
No occupational exposure limits known.
PNEC
freshwater: 0,2 mg/l
marine water: 0,02 mg/l
intermittent release: 0,27 mg/l
sediment (freshwater): 1,18 mg/kg
sediment (marine water): 0,118 mg/kg
soil: 0,117 mg/kg
STP: 10 mg/l
No PNEC oral derived, as accumulation in organisms is not to be expected.
DNEL
worker:
Long-term exposure - local effects, Inhalation: 0,42 mg/m3
8.2. Exposure controls
Personal protective equipment
Respiratory protection:
Respiratory protection in case of vapour/aerosol release. Gas filter for gases/vapours of organic
compounds (boiling point >65 °C, e. g. EN 14387 Type A)
Consider the risk management measures as outlined in the exposure scenario.
Hand protection:
Chemical resistant protective gloves (EN 374)
Suitable materials also with prolonged, direct contact (Recommended: Protective index 6,
corresponding > 480 minutes of permeation time according to EN 374):
butyl rubber (butyl) - 0.7 mm coating thickness
Suitable materials for short-term contact (recommended: At least protective index 2, corresponding >
30 minutes of permeation time according to EN 374)
nitrile rubber (NBR) - 0.4 mm coating thickness
chloroprene rubber (CR) - 0.5 mm coating thickness
Supplementary note: The specifications are based on tests, literature data and information of glove
manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g.
temperature) it must be considered, that the practical usage of a chemical-protective glove in
practice may be much shorter than the permeation time determined through testing.
Manufacturer's directions for use should be observed because of great diversity of types.
Consider the risk management measures as outlined in the exposure scenario.
Eye protection:
Tightly fitting safety goggles (cage goggles) (e.g. EN 166) and face shield.
Consider the risk management measures as outlined in the exposure scenario.
Body protection:
chemical-protection suit (f.e. according to EN 14605)
Consider the risk management measures as outlined in the exposure scenario.
General safety and hygiene measures
Handle in accordance with good industrial hygiene and safety practice. Avoid contact with the skin,
eyes and clothing. Avoid inhalation of vapour. Eye wash fountains and safety showers must be easily
accessible. When using, do not eat, drink or smoke. Hands and/or face should be washed before
breaks and at the end of the shift. Gloves must be inspected regularly and prior to each use.
Replace if necessary (e.g. pinhole leaks). Take off immediately all contaminated clothing. Wash
contaminated clothing before reuse. Store work clothing separately.

Stability and reactivity

10.1. Reactivity
No hazardous reactions if stored and handled as prescribed/indicated.
Reactions with
water/air:
Reaction with: air
Which flammable gases: gases/vapours
Formation of
flammable gases:
Remarks: Forms no flammable gases in the
presence of water.
10.2. Chemical stability
The product is stable if stored and handled as prescribed/indicated.
10.3. Possibility of hazardous reactions
Strong exothermic reaction with acids. Vapours may form ignitable mixture with air.
10.4. Conditions to avoid
Avoid all sources of ignition: heat, sparks, open flame. See SDS section 7 - Handling and storage.
10.5. Incompatible materials
Substances to avoid:
mineral acids, strong oxidizing agents, acid anhydrides, acid chlorides
10.6. Hazardous decomposition products
Hazardous decomposition products:
No hazardous decomposition products if stored and handled as prescribed/indicated.
Possible thermal decomposition products:
carbon monoxide, Carbon dioxide
nitrous gases

Disposal considerations

13.1. Waste treatment methods
Incinerate in suitable incineration plant, observing local authority regulations.
A waste code in accordance with the European waste catalog (EWC) cannot be specified, due to
dependence on the usage.
The waste code in accordance with the European waste catalog (EWC) must be specified in
cooperation with disposal agency/manufacturer/authorities.
Contaminated packaging:
Contaminated packaging should be emptied as far as possible; then it can be passed on for
recycling after being thoroughly cleaned.