Administrative data

Endpoint:
pH
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Experimental result using standard mehtod of analysis

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: OECD 122
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Hydrogen [4-[4-(diethylamino)-2',4'-disulphonatobenzhydrylidene]cyclohexa-2,5-dien-1-ylidene]diethylammonium, sodium salt
EC Number:
204-934-1
EC Name:
Hydrogen [4-[4-(diethylamino)-2',4'-disulphonatobenzhydrylidene]cyclohexa-2,5-dien-1-ylidene]diethylammonium, sodium salt
Cas Number:
129-17-9
Molecular formula:
C27H32N2O6S2.Na
IUPAC Name:
hydrogen [4-[4-(diethylamino)-2',4'-disulphonatobenzhydrylidene]cyclohexa-2,5-dien-1-ylidene]diethylammonium, sodium salt
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Details on test material:
CAs No: 129-17-9Chemical NAme: hydrogen [4-[4-(diethylamino)-2',4'-disulphonatobenzhydrylidene]cyclohexa-2,5-dien-1-ylidene]diethylammonium, sodium saltNature of chemical: Organic

Results and discussion

pH value
pH value:
10.37
Temp.:
30.3 °C
Concentration:
1 other: %w/v
Remarks on result:
other: Basic pH

Any other information on results incl. tables

Method Details

Observations

Remarks if, any

Guideline

OECD 122

 

 

Method

 

pH Meter

 

Principle of method

 

 

 

 

 

 

 

A pH meter is essentially a voltmeter with high input impedance which measures the voltage of an electrode sensitive to the hydrogen ion concentration, relative to another electrode which exhibits a constant voltage.

 

Temperature of 1% w/v test solution

-

30.3 °C

pH (RESULT)

 

-

10.37

Inference

1.   Acidic

2.   Basic

3.   Neutral

 

 

Basic

 

Applicant's summary and conclusion

Conclusions:
pH of 1% w/v aqueous solution of the test item hydrogen [4-[4-(diethylamino)-2',4'-disulphonatobenzhydrylidene]cyclohexa-2,5-dien-1-ylidene]diethylammonium, sodium salt (CAS No. 129-17-9 ) is 10.37 at 30.3 °C indicating alkaline pH of the test solution.
Executive summary:

pH of 1% w/v aqueous solution of the test item hydrogen [4-[4-(diethylamino)-2',4'-disulphonatobenzhydrylidene] cyclohexa-2,5-dien-1-ylidene] diethylammonium, sodium salt (CAS No. 129-17-9 ) is 10.37 at 30.3 °C indicating alkaline pH of the test solution.