Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Key result
Flash point:
>= 138 - <= 142 °C
Atm. press.:
103.7 kPa
Conclusions:
The flash point of the test material has been determined to be 140 ± 2 °C.
Executive summary:

The flash point of the test material has been determined using a closed cup equilibrium method, Method A9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008 in accordance with Council Directive 98/8/EC, Annex ll and US EPA Office of Prevention, Pesticides and Toxic Substances, Series 830: Product Properties Test Guidelines. The test material was determined to have a flash point of 140 ± 2 °C.

Description of key information

Flash point 140 °C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
413.2 K

Additional information

The flash point of the test material has been determined using a closed cup equilibrium method, Method A9 and US EPA Office of Prevention, Pesticides and Toxic Substances, Series 830: Product Properties Test Guidelines. The test material was determined to have a flash point of 140 ± 2 °C.