Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
yes
Type of method:
static method
Test no.:
#3
Temp.:
10 °C
Vapour pressure:
15.2 Pa
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
30.8 Pa
Test no.:
#2
Temp.:
30 °C
Vapour pressure:
56.2 Pa

Description of key information

Key value for chemical safety assessment

Vapour pressure:
30.8 Pa
at the temperature of:
20 °C

Additional information