Registration Dossier

Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17.01.2018 - 06.02.2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.5 (Surface Tension)
Deviations:
not specified
GLP compliance:
not specified
Other quality assurance:
other: UNI EN ISO 9001:2015
Remarks:
Chemical, technological, sanitary and eco-toxicological analyses. Technical and scientific services, consulting and design of materials for biomedical and technological manufacturing fields (IAF 34)
Type of method:
OECD harmonised ring method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
impurity
Test material form:
not specified
Details on test material:
not specified
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 20170710
- Expiration date of the lot/batch: not specified
- Purity test date: not specified

RADIOLABELLING INFORMATION (if applicable) not applicable


STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: 4°C
- Stability under test conditions: not specified
- Solubility and stability of the test substance in the solvent/vehicle: not specified
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium: not relevant

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: not specified
- Preliminary purification step (if any): not relevant
- Final dilution of a dissolved solid, stock liquid or gel: not relevant
- Final preparation of a solid: not relevant

FORM AS APPLIED IN THE TEST (if different from that of starting material) liquid (solution)

TYPE OF BIOCIDE/PESTICIDE FORMULATION (if applicable) not applicable

OTHER SPECIFICS: not specified

Results and discussion

Surface tension
Key result
Surface tension:
0.079 other: N/mm
Temp.:
18.4 °C
Conc.:
88 other: wt

Applicant's summary and conclusion

Conclusions:
The surface tension of the substance tested according to A.5 test method is 0,079 N/mm.