Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
substances / mixtures which in contact with water emit flammable gases
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17.01.2018 - 06.02.2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.12 (Flammability (Contact with Water))
Deviations:
not specified
GLP compliance:
not specified
Other quality assurance:
other: UNI EN ISO 9001:2015
Remarks:
Chemical, technological, sanitary and eco-toxicological analyses. Technical and scientific services, consulting and design of materials for biomedical and technological manufacturing fields (IAF 34)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
impurity
Test material form:
not specified
Details on test material:
not specified
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material:
20170710
- Expiration date of the lot/batch:
not specified
- Purity test date:
not specified

RADIOLABELLING INFORMATION (if applicable)
not applicable
- Radiochemical purity:
- Specific activity:
- Locations of the label:
- Expiration date of radiochemical substance:

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material:
4°C
- Stability under test conditions:
not specified
- Solubility and stability of the test substance in the solvent/vehicle:
not specified
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium:
not relevant

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing:
not specified
- Preliminary purification step (if any):
not relevant
- Final dilution of a dissolved solid, stock liquid or gel:
not relevant
- Final preparation of a solid:
not relevant

FORM AS APPLIED IN THE TEST (if different from that of starting material)
liquid (solution)

TYPE OF BIOCIDE/PESTICIDE FORMULATION (if applicable)
not applicable

OTHER SPECIFICS: 1 g of sample was weighted and tested.

Results and discussion

Substances / mixtures which in contact with water emit flammable gases
Key result
Test procedure:
step 1
step 2
step 3
step 4
Identity of evolved gas:
not applicable as no gas evolved
Remarks on result:
no reaction with water observed

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The substance was tested according to A.12 method and it was judged as no flammable or no highly flammable.