Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
other: Publication
Adequacy of study:
key study
Study period:
2005
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
not specified
GLP compliance:
yes
Type of method:
gas saturation method
Key result
Test no.:
#1
Temp.:
25 °C
Vapour pressure:
0 hPa

A vapour pressure at 25 degree C was calculated by extrapolation based on data at 40, 45 and 50 degree C.

Conclusions:
The vapour pressure of p-toluic acid was determined to be 0.0000811 hPa at 25°C. A vapour pressure at 25°C was calculated by extrapolation based on data at 40, 45 and 50°C

Description of key information

The vapour pressure of p-toluic acid was determined to be 0.0000811 hPa at 25°C.

Key value for chemical safety assessment

Vapour pressure:
0 hPa
at the temperature of:
25 °C

Additional information