Registration Dossier

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 October 2017 to 21 January 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
GLP compliance:
yes
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material:
CCI Corp. / Bx 20170320
- Expiration date of the lot/batch:
19 March 2018
- Purity test date:
20 march 2017

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material:
stored at room temperature with no direct exposure to sunlight.
- Stability under test conditions:
stable
- Solubility and stability of the test substance in the solvent/vehicle:
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium:

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing:
- Preliminary purification step (if any):
- Final dilution of a dissolved solid, stock liquid or gel:
- Final preparation of a solid:

FORM AS APPLIED IN THE TEST (if different from that of starting material)

TYPE OF BIOCIDE/PESTICIDE FORMULATION (if applicable)

OTHER SPECIFICS:
Key result
Relative self-ignition temperature:
> 400 °C
Remarks on result:
no self ignition observed under the test conditions
Conclusions:
No ignition was observed up to 400°C, therefore not classified as self-igniting.

Description of key information

No ignition was observed up to 400°C, therefore not classified as self-igniting.

Key value for chemical safety assessment

Additional information