Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Non-GLP but proprietary study.
Cross-referenceopen allclose all
Reason / purpose:
reference to same study
Reason / purpose:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report Date:
2009

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
not specified

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Molecular mass: 141.93 g/mol
Lot: 709018
Purity: 97%
Physical state: dark violet, odourless powder

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

A preliminary test was performed to determine if the main test needs to be performed.

When the pile was ignited and burned over a distance of 200 mm during 4 minutes, the test has to be performed. However, if there was no ignition of the test item or the pile burned slower than 200 mm during 4 minutes, the main test is unnecessary.

The test item could not be ignited with a flame because it decomposed during the heating. The colour of the test item changed from dark violet to grayish. Consequently, the main test was not necessary.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The test item could not be ignited with a flame because it decomposed during the heating. The colour of the test item changed from dark violet to grayish. Consequently, the main test was not necessary.
It can be concluded that the test item is not a highly flammable solid.
Executive summary:

The test item could not be ignited with a flame because it decomposed during the heating. The colour of the test item changed from dark violet to grayish. Consequently, the main test was not necessary.

It can be concluded that the test item is not a highly flammable solid.