Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2004
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Basic data given: comparable to guidelines/standards (VDI 2263 sheet 1)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2004
Report date:
2004

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
other: VDI 2263 sheet 1
Principles of method if other than guideline:
Determination of the "Brennzahl" (see below)

Test material

Constituent 1
Chemical structure
Reference substance name:
2-[(4-chloro-2-nitrophenyl)azo]-N-(2-chlorophenyl)-3-oxobutyramide
EC Number:
229-355-1
EC Name:
2-[(4-chloro-2-nitrophenyl)azo]-N-(2-chlorophenyl)-3-oxobutyramide
Cas Number:
6486-23-3
Molecular formula:
C16H12Cl2N4O4
IUPAC Name:
2-[(4-chloro-2-nitrophenyl)diazenyl]-N-(2-chlorophenyl)-3-oxobutanamide
Test material form:
solid: nanoform, no surface treatment

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
not determinable

Any other information on results incl. tables

The sample melts if ignition is attempted with a flame or a hot platinium wire. No further reaction is observed uption ignition attempt with a flame. With the hot platinium wire, the melting sample briefly flared up but the flame immediately extinguished upon removal of the wire.

The test substance is assigned to combustion class 2: "catches fire briefly and extinguishes rapidly" ("Brennzahl" 2 definition according to HVBG, 2001).

As the flame does not propagate no burning rate can be determined.

Reference: HVBG, Hauptverband der gewerblichen Berufsgenossenschaften: GESTIS-DUST-EX Database - combustion and explosve characteristics of dusts, Edition 2/2001 HVBG, Sankt Augustin, 2001 

Applicant's summary and conclusion

Interpretation of results:
non flammable
Conclusions:
The test substance does not burn independently at room temperature (combustion class 2).
Executive summary: