Registration Dossier

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The boiling point can not be determined due to reaction and/or decomposition of the test substance.

Key value for chemical safety assessment

Additional information

The melting and boiling temperature of the test substance were determined in a GLP study according to OECD and EU guidelines. The experiment was performed using a differential scanning calorimetry (DSC).

No effects were observed which were due to melting and/or boiling of the test substance. An exothermic peak was observed between 100°C and 400°C. The effect was due to reaction and/or decomposition of the test substance. After the experiment, a white residue remained in the sample container.

It can as a consequence be concluded that no boiling point can be determined for this test substance.