Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
August 18th and 30th, 2011.
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report Date:
2011

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: solid in non-homogenous pieces
Details on test material:
Name: CarboNeXT
Physical state: solid in non-homogenous pieces
Odour: characteristic
Container: plastic bag

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: No propagation on 200 mm within 4 minutes

Any other information on results incl. tables

Preliminary screening test

The specimen prepared with the ground sample ignites on contact with a Bunsen burner flame and after being removed from the burner, the flame goes out; after, the generated smoke and presence of embers that propagate slowly are observed. After 4 minutes, from when it is removed from the Bunsen burner flame, one notes propagation for approximately 15 mm in length on the specimen without any further embers or smoke.

The sample indicated asCarboNeXT, not propagating combustion on 200 mm within 4 minutes, must not be considered easily flammable and further tests were not conducted, pursuant to the method.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
CarboNeXT does not propaga combustion on 200 mm within 4 minutes and must not be considered easily flammable.