Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 October 2017 to 21 January 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
GLP compliance:
yes
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material:
CCI Corp. / Bx 20170320
- Expiration date of the lot/batch:
19 March 2018
- Purity test date:
20 march 2017

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material:
stored at room temperature with no direct exposure to sunlight.
- Stability under test conditions:
stable
- Solubility and stability of the test substance in the solvent/vehicle:
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium:

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing:
- Preliminary purification step (if any):
- Final dilution of a dissolved solid, stock liquid or gel:
- Final preparation of a solid:

FORM AS APPLIED IN THE TEST (if different from that of starting material)

TYPE OF BIOCIDE/PESTICIDE FORMULATION (if applicable)

OTHER SPECIFICS:
Key result
Relative self-ignition temperature:
> 400 °C
Remarks on result:
no self ignition observed under the test conditions
Conclusions:
No ignition was observed up to 400°C, therefore not classified as self-igniting.

Description of key information

No ignition was observed up to 400°C, therefore not classified as self-igniting.

Key value for chemical safety assessment

Additional information

No ignition was observed up to 400°C, therefore not classified as self-igniting.