Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
other distribution data
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Scientifically acceptable method, expert judgement.

Data source

Reference
Title:
No information
Author:
BASF AG (2007). Department of product safety, data assessment, 16 Jul 2007.

Materials and methods

Principles of method if other than guideline:
Method: other: calculated
Type of study:
volatility
Media:
water - air

Test material

Constituent 1
Chemical structure
Reference substance name:
Pentacarbonyliron
EC Number:
236-670-8
EC Name:
Pentacarbonyliron
Cas Number:
13463-40-6
Molecular formula:
C5FeO5
IUPAC Name:
pentacarbonyliron
Details on test material:
TS-Freetext:
Pentacarbonyliron
CAS: 13463-40-6

Results and discussion

Any other information on results incl. tables

RS-Freetext:
Henry´s law constant (20°C) of pentacarbonyliron, calculated as the ratio of vapour pressure (2799 Pa; Kirk-Othmer (1991)) and water solubility (44 g/m3 = 0.225 mol/m3; BASF AG (2007), Report No. 2007.015)) = 12404 Pa*m3/mol

Applicant's summary and conclusion