Registration Dossier

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: scientifically acceptable

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1971
Report Date:
1971

Materials and methods

Principles of method if other than guideline:
other: measured
GLP compliance:
no
Type of method:
capillary viscometer (static)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Name of test material (as cited in study report): pentacarbonyliron
Analytical purity: pure

Results and discussion

Viscosityopen allclose all
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
0.76
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
0.66

Any other information on results incl. tables

measured from 0 - 40 °C

Applicant's summary and conclusion