Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21. april 2004 - 9. june 2004
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: well documented and reported study, conducted according to internationally accepted technical guideline. A GLP compliance statement and a Quality Assurance Uni Statement is included in the report.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2004
Report date:
2004

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
[(2S,3R,5S)-3-[(4-methylbenzoyl)oxy]-5-(5-methyl-2,4-dioxo-3,4-dihydropyrimidin-1(2H)-yl)tetrahydrofuran-2-yl]methyl 4-methylbenzoate
EC Number:
608-497-1
Cas Number:
3056-13-1
Molecular formula:
C26 H26 N2 O7
IUPAC Name:
[(2S,3R,5S)-3-[(4-methylbenzoyl)oxy]-5-(5-methyl-2,4-dioxo-3,4-dihydropyrimidin-1(2H)-yl)tetrahydrofuran-2-yl]methyl 4-methylbenzoate

Results and discussion

Any other information on results incl. tables

After removing the gas burner the flame extinguished and the test substance did not burn over a length of 200 mm. Therefore according to the guideline no further test was performed. The drying loss of the test substance is 0.1 %, according to the certificate of analysis.

Therefore the test substance is not classified as "highly flammable".

Applicant's summary and conclusion

Conclusions:
The test substance powder train did not burn over a length of 200 mm. Therefore the test substance is not classified as "highly flammable".