Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18 Apr 1995 to 06 Aug 1995
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: done under GLP and OECD method

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1995
Report Date:
1995

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
Directive 92/69/EEC
GLP compliance:
yes
Type of method:
isoteniscope

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressure
Temp.:
298.15 K
Vapour pressure:
1.9 Pa

Any other information on results incl. tables

The sample showed some slight darkening during the 4 runs that were performed.

Applicant's summary and conclusion

Conclusions:
Vapour Pressure determined to be 1.9 Pa at 298.15K