Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-03-13
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
- Batch No.of test material: 20141015
- Purity: 99.35%
- Expiration date of the lot/batch: January 2019
- Stability under test conditions: Room temperature
Key result
Flash point:
112.5 °C
Atm. press.:
101.1 kPa
Remarks on result:
other: Corrected due to barometric pressure

Full test results:

Temperature (°C)

Barometric Pressure (kPa)

Ignition?

Yes (y) / No (n)

Halo/Enlarged test flame?

Yes (y) / No (n)

Evaluation Run

25-111

100.1

n

n/a

112

100.1

y

n/a

                                                                       Run1                                                                   

90-111

100.1

n

n/a

112.1

100.1

y

n/a

Run 2

90-113

100.1

n

n/a

114.1

100.1

y

n/a

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item has been determined to be 112.5 °C using a closed cup equilibrium method.

Description of key information

The flash point of the substance was determined in a GLP-compliant study according to test method EC A.9 (K1, Dekra, 2018). The flash point of the test item has been determined to be 112.5 °C using a closed cup equilibrium method.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
112.5 °C

Additional information