Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 2018-02-07 to 2018-02-13
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
static method
Specific details on test material used for the study:
- Batch No.of test material: 20141015
- Purity: 99.35%
- Expiration date of the lot/batch: January 2019
- Stability under test conditions: Room temperature
Key result
Temp.:
20 °C
Vapour pressure:
8.5 Pa
Remarks on result:
other: mean of runs 1 & 2

Full test results:

Temp / °C

Temp / K

P / mbar

P / Pa

Run 1

*20

293.15

0.09

9

20.6

293.75

0.0911

9.11

29.8

302.95

0.172

17.2

39.9

313.05

0.2887

28.87

50.0

323.15

0.5398

53.98

Run 2

*20

293.15

0.08

8

20.9

294.05

0.081

8.1

30.5

303.65

0.166

16.6

40.1

313.25

0.2687

26.87

50.0

323.15

0.4655

46.55

* Determined by extrapolation

Run 1: 10.8 g of sample was degassed for a 70 hour period. Starting vacuum pressure was 0.0063 mbar.

Run 2: 12.5 g of sample was degassed for a 94 hour period. Starting vacuum pressure was 0.0029 mbar.

Conclusions:
The vapor pressure of the test item has been determined to be 8.5 Pa at 20 ºC.

Description of key information

A GLP-compliant study was performed to determine the vapour pressure according to EU Method A.4 without deviations (K1, Dekra, 2018). A vapour pressure of 8.5 Pa was determined at 20°C using the vapour pressure balance method.

Key value for chemical safety assessment

Vapour pressure:
8.5 Pa
at the temperature of:
20 °C

Additional information