Registration Dossier

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guidelline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1996
Report Date:
1996

Materials and methods

Test guideline
Guideline:
EU Method A.6 (Water Solubility)
GLP compliance:
yes (incl. certificate)
Type of method:
flask method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Details on test material:
Name of test material (as cited in study report): 625-Triketon
Analytical purity: 99.4g/100g
Lot/batch No.: LJ 27881/1

Results and discussion

Water solubility
Water solubility:
8.9 mg/L
Temp.:
25 °C
pH:
4.8

Any other information on results incl. tables

Result:

 Batch  Amount of test substance [g]   Amount of water [g] Residence time at 33°C [h]   Residence time at RT [h]  pH value of the saturated water solution Concentration of test substance in the sat. water solution [mg/l]  
 1  1,8574 92,6713  24   24 4,82  8,83 
 2  2,0083 91,9329 48  72 4,85 8,96 
 3  2,5119 90,4139 120  48 4,79  8,92 

Applicant's summary and conclusion