Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 258-436-4 | CAS number: 53220-22-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Study period:
- 2012-06-21 to 2012-06-22
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
- Version / remarks:
- adopted 13th April 2004
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient)
- Version / remarks:
- May 2008
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 830.7570 (Partition Coefficient, n-octanol / H2O, Estimation by Liquid Chromatography)
- Version / remarks:
- August 1996
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
- Analytical method:
- high-performance liquid chromatography
- Key result
- Type:
- log Pow
- Partition coefficient:
- > 6.5
- Temp.:
- 25 °C
- pH:
- 6.4
- Details on results:
- In the course of this study the partition coefficient (Pow) of ditetradecyl peroxydicarbonate was determined using high performance liquid chromatography.
Because of the test item properties a short HPLC column and mobile phase with high elution strength had to be applied. Under these circumstances the retention times of the reference items were below 1 minute.
The correlation coefficient R for the relationship between log k and log Pow of the reference item is 0.959.
The short retention times and the relatively high standard deviations (CV%) caused that quality criteria were not met, as values of log Pow derived from individual measurements did not fall within a range of 0.1 log units.
Retention time of ditetradecyl peroxydicarbonate (35.52 minures) is significantly higher than the last eluting standard (DDT) (0.81 minutes); therefore an accurate value of log Pow could not be given. As quality criteria of the calibration data were not met and the estimated partition coefficient of the test item is much more greater than the last eluting standard; the extrapolated log Pow value was not calculated, but the result is considered scientifically valid.
The estimated log Pow of ditetradecyl peroxydicarbonate is > 6.5. - Conclusions:
- Using the HPLC method the n-octanol/water partition coefficient of ditetradecyl peroxydicarbonate was determined to be much higher than the last eluting standard (DDT). The estimated log Pow of ditetradecyl peroxydicarbonate is > 6.5.
- Executive summary:
The partition coefficient (n-octanol/water) of ditetradecyl peroxydicarbonate was estimated using the HPLC method according to EU method A.8, OECD guideline no. 117 and OPPTS guideline 830.7570. The n-octanol/water partition coefficient of ditetradecyl peroxydicarbonate was determined to be much higher than the last eluting standard (DDT). The estimated log Pow of ditetradecyl peroxydicarbonate is > 6.5.
- Endpoint:
- partition coefficient
- Type of information:
- (Q)SAR
- Adequacy of study:
- weight of evidence
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- results derived from a valid (Q)SAR model, but not (completely) falling into its applicability domain, with adequate and reliable documentation / justification
- Justification for type of information:
- Please refer to the QMRF and QPRF files provided under the section attached justification.
- Qualifier:
- according to guideline
- Guideline:
- other: REACH guidance on QSAR R.6
- Principles of method if other than guideline:
- Estimates the log octanol-water partition coefficient, log KOW, of chemicals using an atom/fragment contribution method.
- GLP compliance:
- no
- Type of method:
- calculation method (fragments)
- Partition coefficient type:
- octanol-water
- Specific details on test material used for the study:
- SMILES: CCCCCCCCCCCCCCOC(=O)OOC(=O)OCCCCCCCCCCCCCC
- Key result
- Type:
- log Pow
- Partition coefficient:
- 13
- Temp.:
- 25 °C
- Remarks on result:
- other: QSAR predicted value. The substance is not within the applicability domain of the model.
- Conclusions:
- Using KOWWIN v1.68 the logPow of the test item was calculated to be 13.0 at 25 °C. The substance is not within the applicability domain of the model. Thus the estimation may be less accurate.
- Executive summary:
The logPow was calculated using KOWWIN v1.68 as part of EPISuite v4.11 from US Environmental Protection Agency.
Using KOWWIN v1.68 the log Kow of the test item was calculated to be 13.0 at 25 °C (EPI Suite, 2014).
The adequacy of a prediction depends on the following conditions:
a) the (Q)SAR model is scientifically valid: the scientific validity is established according to the OECD principles for (Q)SAR validation;
b) the (Q)SAR model isapplicable to thequery chemical: a (Q)SAR is applicable if the query chemical falls within the defined applicability domain of the model;
c) the (Q)SAR result is reliable: a valid (Q)SAR that is applied to a chemical falling within its applicability domain provides a reliable result;
d) the (Q)SAR model isrelevant for theregulatory purpose.
For assessment and justification of these 4 requirements the QMRF and QPRF files were developed and attached to this study record.
Description of the prediction Model
The prediction model was descripted using the harmonised template for summarising and reporting key information on (Q)SAR models. For more details please refer to the attached QSAR Model Reporting Format (QMRF) file.
Assessment of estimation domain
The assessment of the estimation domain was documented in the QSAR Prediction Reporting Format file (QPRF). Please refer to the attached document for the details of the prediction and the assessment of the estimation domain.
Referenceopen allclose all
TYPE |
NUM |
LOGKOW FRAGMENT DESCRIPTION |
COEFF |
VALUE |
Frag |
2 |
-CH3 [aliphatic carbon] |
0.5473 |
1.0946 |
Frag |
26 |
-CH2- [aliphatic carbon] |
0.4911 |
12.7686 |
Frag |
2 |
-OC(=O)O- [carbonate,aliphatic attach] |
-1.0900 |
-2.1800 |
Factor |
1 |
-C(=O)-O-O-C(=O)- correction |
1.1000** |
1.1000 |
Const |
|
Equation Constant |
|
0.2290 |
Description of key information
QSAR calculation resulted in a logPow value of 13.01.
Key value for chemical safety assessment
- Log Kow (Log Pow):
- 13
- at the temperature of:
- 25 °C
Additional information
Using the HPLC method the n-octanol/water partition coefficient of ditetradecyl peroxydicarbonate was determined to be much higher than the last eluting standard (DDT). The estimated log Pow of the test item is > 6.5.
QSAR calculation resulted in a logPow value of 13.01.
Since it is technically not feasible with the available experimental methods to determine partition coefficients > 8 (ECHA guidance on CSA & IR, 7a (2017)), the modelled value of 13 is considered to be more reliable and thus applied as key value for the CSA.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.