Registration Dossier

Administrative data

First-aid measures

General advice
Take off all contaminated clothing immediately. Never give anything by mouth to an unconscious person. Remove from exposure, lie down. In the case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).

Inhalation
Remove to fresh air. Call a physician immediately.

Skin contact
Wash off immediately with soap and plenty of water.

Eye contact
In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice.

Ingestion
Clean mouth with water and drink afterwards plenty of water. If a person vomits when lying on his back, place him in the recovery position. Do not induce vomiting. If swallowed, seek medical advice immediately and show this container or label.

Fire-fighting measures

Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Unsuitable extinguishing media
High volume water jet

Specific hazards
Cool closed containers exposed to fire with water spray. Do not allow run-off from fire fighting to enter drains or water courses.

Special protective equipment for fire-fighters
Use personal protective equipment

Further information
Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.

Accidental release measures

Personal precautions
Wear respiratory protection. Wear personal protective equipment.

Environmental precautions
Avoid subsoil penetration. Do not allow material to contaminate ground water system. Do not contaminate water. If the product contaminates rivers and lakes or drains inform respective authorities. Do not let product enter drains.

Methods for cleaning up
Remove mechanically and with care (e.g. with clean polyethylene plastic shovel). Contain and collect spillage with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations.

Additional advice
Never add other substances or waste material to product residue. Move product residue to a safe place and dispose of properly.

Handling and storage

Handling
For personal protection see section exposure controls/personal protection

Storage
Requirements for storage areas and containers
Electrical installations / working materials must comply with the technological safety standards. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Keep container tightly closed. No smoking.

Further information on storage conditions
Avoid impurities {e.g. rust, dust, ash), risk of decomposition.

Advice on common storage
Store apart from other dangerous and incompatible substances.

Storage temperature
<20 °C

Transport information

Land transport (ADR/RID)

UN number:
3116
Proper shipping name and description:
ORGANIC PEROXIDE TYPE D, SOLID, TEMPERATURE CONTROLLED
Chemical name:
Dimyristyl peroxydicarbonate
Language:
English
Class:
5.2
Classification code:
P2
Packaging group:
--
Labels:
5.2
SpecialProvisionsopen allclose all

Inland waterway transport (ADN(R))

UN number:
3116
Proper shipping name and description:
ORGANIC PEROXIDE TYPE D, SOLID, TEMPERATURE CONTROLLED
Chemical name:
Dimyristyl peroxydicarbonate
Language:
English
Class:
5.2
Classification code:
P2
Packaging group:
--
Labels:
5.2
Remarksopen allclose all

Marine transport (IMDG)

UN number:
3116
Proper shipping name and description:
ORGANIC PEROXIDE TYPE D, SOLID, TEMPERATURE CONTROLLED
Chemical name:
Dimyristyl peroxydicarbonate
Class:
5.2
Packaging group:
P2
Labels:
5.2
Remarksopen allclose all

Air transport ICAO/IATA

UN number:
3116
Proper shipping name and description:
ORGANIC PEROXIDE TYPE D, SOLID, TEMPERATURE CONTROLLED
Chemical name:
Dimyristyl peroxydicarbonate
Class:
5.2
Packaging group:
P2
Labels:
5.2
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Components with workplace control parameters
Contains no substances with occupational exposure limit values.

Engineering measures
Provide adequate ventilation.

Personal protective equipment

Respiratory protection
Short duration filter unit: Filter A

Hand protection
Material: butyl-rubber
Glove thickness: 0,5 mm
Break through time: >=8h
Remarks: Skin should be washed after contact.

Eve protection
Tightly fitting safety goggles. Face protection

Skin and body Protection
Protective suit
Remove and wash contaminated clothing before re-use.

Hygiene measures
Wash hands before breaks and immediately after handling the product.
Keep away from food, drink and animal feeding stuffs.

Stability and reactivity

Conditions to avoid
Keep away from heat and sources of ignition

Materials to avoid
Accelerators, strong acids and bases, heavy metals and heavy metal salts, reducing agents, Avoid impurities (e.g. rust, dust, ash), risk of decomposition.

Hazardous decomposition products
Irritant, caustic, flammable, noxious/toxic gases and vapours can develop in the case of fire and decomposition

Thermal decomposition
ca. 35 °C Method: SADT (UN test H.4)
Note: SADT possible at temperatures above approximately 35 °C.

Hazardous reactions
Vapours may form explosive mixture with air.

Stability
Stable under recommended storage conditions.

Disposal considerations

Advice on disposal and packaging
Disposal:
Dispose of in conjunction with appropriate waste disposal authorities and in accordance with disposal regulations. Waste codes should be assigned by the user based on the application for which the product was used.