Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-04-21
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to other study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Key result
Flash point:
109.6 °C
Atm. press.:
97.9 kPa

The atmospheric pressure during the test was 97.9 kPa.The results of the 4 repeat determinations of the flash point for the test substance were: 108.0 °C, 108.0 °C, 110.0 °C and 109.0 °C.
The corrected mean flash point of the test substance
is 109.6 °C, standard deviation 0.96,

4 determinations.

Conclusions:
The corrected mean flash point of the test substance is 109.6 °C, standard deviation 0.96, 4 determinations.
Executive summary:

The determination of the flash point of the test substance was performed by the Pensky-Martens closed cup method

The atmospheric pressure during the test was 97.9 kPa.

The results of the 4 repeat determinations of the flash point for the test substance were: 108.0 °C, 108.0 °C, 110.0 °C and

109.0 °C.
The corrected mean flash point of the test substance is 109.6 °C, standard deviation 0.96,

4 determinations.

Description of key information

Flash Point (EU Method A.9, ISO 2719:2002). The corrected flash point is 109.6 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
109.6 °C

Additional information

The determination of the flash point of the test substance was performed by the Pensky-Martens closed cup method.

The atmospheric pressure during the test was 97.9 kPa. The corrected mean flash point is 109.6 °C.