Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-04-21
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to other study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Key result
Flash point:
109.6 °C
Atm. press.:
97.9 kPa

The atmospheric pressure during the test was 97.9 kPa.The results of the 4 repeat determinations of the flash point for the test substance were: 108.0 °C, 108.0 °C, 110.0 °C and 109.0 °C.
The corrected mean flash point of the test substance
is 109.6 °C, standard deviation 0.96,

4 determinations.

Conclusions:
The corrected mean flash point of the test substance is 109.6 °C, standard deviation 0.96, 4 determinations.
Executive summary:

The determination of the flash point of the test substance was performed by the Pensky-Martens closed cup method

The atmospheric pressure during the test was 97.9 kPa.

The results of the 4 repeat determinations of the flash point for the test substance were: 108.0 °C, 108.0 °C, 110.0 °C and

109.0 °C.
The corrected mean flash point of the test substance is 109.6 °C, standard deviation 0.96,

4 determinations.

Description of key information

Flash Point (EU Method A.9, ISO 2719:2002). The corrected flash point is 109.6 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
109.6 °C

Additional information

The determination of the flash point of the test substance was performed by the Pensky-Martens closed cup method.

The atmospheric pressure during the test was 97.9 kPa. The corrected mean flash point is 109.6 °C.