Registration Dossier

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Endpoint:
boiling point
Type of information:
other: handbook data
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Handbook data considered to be from a trusted source acc. to "ECHA, Guidance on information requirements and chemical safety assessment – Chapter R.7a: Endpoint specific guidance".

Data source

Reference
Reference Type:
review article or handbook
Title:
CRC Handbook of Chemistry and Physics
Author:
Lide, D.R. (ed.)
Year:
2008
Bibliographic source:
88th ed. Boca Raton, FL: CRC Press Inc.

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Not applicable - Handbook data
GLP compliance:
not specified
Type of method:
other: no data

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: crystalline
Details on test material:
Molecular formula: BaCl2
Molecular weight: 208.23 g/mol
No further details are given.

Results and discussion

Boiling point
Boiling pt.:
1 560 °C
Atm. press.:
ca. 1 013.25 mBar

Applicant's summary and conclusion

Conclusions:
According to the reference, the boiling point of barium dichloride is 1560°C at atmospheric pressure.