Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25-04-2017 – 25-04-2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
ISO No., other: OECD 103
Principles of method if other than guideline:
The flash point determination of Test item was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus.
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
104.6 °C
Atm. press.:
971.1 hPa
Remarks on result:
other: No other detail available

Observation Table :

 Method Details    Observations  Remarks if, any
 Method

 The flash point of a flammable

liquid is the lowest temperature at

which there will be enough

flammable vapor to ignite when an

ignition source is applied.

                        
 Type of method  Closed cup  
Flash point apparatus

 Abel’s flash pt apparatus

Pensky-Martens flash point

apparatus

 

Pensky-Martens flash

point apparatus

Quantity of chemical

used

 g/ml

5.005 g

Ignition source 

 Gas lighter/flame

 Gas lighter

 Atmospheric pressure

 hPa

 971.1hPa

Mean Flash point

(RESULT)

 °C

 104.6°C

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point determination of Test item was done. The method is closed cup method using Pensky-Martens Flash Point Apparatus. The meanflash point of the test item was determine to be 104.6°C at 971.1 hPa.
Executive summary:

The flash point determination of Test item was done. The method is closed cup method using Pensky-Martens Flash Point Apparatus. The meanflash point of the test item was determine to be 104.6°C at 971.1 hPa.

Description of key information

The flash point determination of Test item was done. The method is closed cup method using Pensky-Martens Flash Point Apparatus. The meanflash point of the test item was determine to be 104.6°C at 971.1 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
104.6 °C

Additional information

The flash point determination of Test item was done. The method is closed cup method using Pensky-Martens Flash Point Apparatus. The meanflash point of the test item was determine to be 104.6°C at 971.1 hPa.

From other reliable sources & authoritative databases flash point of test chemical is determine to be 129°C or 264°F.