Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study obtained through inquiry process; SNIF file obtained from ECHA.

Data source

Reference
Reference Type:
other: SNIF
Title:
Unnamed
Year:
1997

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
not specified
GLP compliance:
yes
Type of method:
other: Thermogravimetry: diffusion controlled evaporation

Test material

Constituent 1
Reference substance name:
Body responsible for the test
IUPAC Name:
Body responsible for the test
Test material form:
not specified

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
< 0 Pa
Temp.:
25 °C
Vapour pressure:
< 0 Pa

Applicant's summary and conclusion

Conclusions:
vapour pressure at 20°C < 0.00000026 Pa,
vapour pressure at 25°C < 0.00000063 Pa
Executive summary:

The vapour pressure of the test substance has been determined to be < 0.00000026 Pa at 20 °C and < 0.00000063 Pa at 25 °C in a GLP study according to EU Method A.4 (thermogravimetry: diffusion controlled evaporation).