Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Qualifier:
equivalent or similar to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
not specified
GLP compliance:
yes
Type of method:
static method
Temp.:
20 °C
Vapour pressure:
27 Pa
Temp.:
40 °C
Vapour pressure:
> 40 - < 53 Pa
Temp.:
82 °C
Vapour pressure:
1.33 kPa

Description of key information

27 Pa at 20 °C

40 – 53 Pa at 40 °C

1.33 kPa at 82 °C

Key value for chemical safety assessment

Vapour pressure:
27 Pa
at the temperature of:
20 °C

Additional information