Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 939-457-4 | CAS number: 1469983-50-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Boiling point
Administrative data
Link to relevant study record(s)
- Endpoint:
- boiling point
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- From 16 May 2012 to 25 January 2013
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Reason / purpose for cross-reference:
- reference to same study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 103 (Boiling point/boiling range)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.2 (Boiling Temperature)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- 2012-12-15
- Type of method:
- differential scanning calorimetry
- Key result
- Boiling pt.:
- >= 280 - <= 281 °C
- Atm. press.:
- 1 013 hPa
- Conclusions:
- The mean corrected boiling point of the test item is 280.5 ± 0.5°C .
- Executive summary:
The boiling melting point of the test item (= substance EC 939-455-3) was investigated in a GLP-compliant study performed in accordance with OECD Guideline 103 (Boiling point/boiling range) and EU Method A.2 (Boiling Temperature). The mean boiling point of the test item was 280.5 ± 0.5°C.
- Endpoint:
- boiling point
- Type of information:
- read-across from supporting substance (structural analogue or surrogate)
- Adequacy of study:
- key study
- Justification for type of information:
- 1. HYPOTHESIS FOR THE ANALOGUE APPROACH
C8-C18 AAPHS and C12-18 AAPHS have the same functional groups, and general composition. The main variable resides in the alkyl chain distribution.
2. SOURCE AND TARGET CHEMICAL(S) (INCLUDING INFORMATION ON PURITY AND IMPURITIES)
Source chemical = C8-18 cocamidopropyl hydroxysultaine (EC 939-455-3).
Target chemical = C12-18 cocamidopropyl hydroxysultaine (EC 939-457-4).
3. ANALOGUE APPROACH JUSTIFICATION
The alkyl C-chain distribution of the source chemical significantly overlaps with the one of the target chemical, the C12-alkyl derivative being the major constituent in both chemicals. The structural differences in side C-chains is not expected to lead to significant differences on phys-chem properties.
4. DATA MATRIX
See "Documentation and scientific justification of the read-across approach" in section 13.2. - Reason / purpose for cross-reference:
- read-across source
- Key result
- Boiling pt.:
- >= 280 - <= 281 °C
- Atm. press.:
- 1 013 hPa
- Remarks on result:
- other: read-across from EC 939-455-3
- Conclusions:
- By analogy with the source substance EC 939-455-3, a boiling point of 280.5 ± 0.5°C was reported for the target substance 1-Propanaminium, N-(3-aminopropyl)-2-hydroxy-N,N-dimethyl-3-sulfo-, N-(C12-18(even numbered) acyl) derivs., hydroxides, inner salts (EC 939-457-4).
Referenceopen allclose all
Six assays were performed during the test, the temperature values obtained for the corrected boiling point varied between 280.4 and 281.8 °C. The mean value for the boiling point is explained as the mean of at least two assays for which the boiling point value are in
the range of the estimated accuracy of the method: ± 0.5 °C up to 326.9 °C and ± 2.0 °C above 326.9 °C.
Two assays were contained between the range for the boiling point and two assays.
Assays N° | Boiling point (°C) |
1 | / |
2 | 281.8 |
3 | 280.6 |
4 | 280.4 |
5 | 281.8 |
6 | / |
/ corresponds to the non integration of the curve.
The results written in bold were taken into account.
Description of key information
As the boiling point of the substance EC 939-457-4 has not been determined experimentally, a read-across approach was followed to fill in the endpoint. The boiling point of a structural analogue substance (= source substance EC 939-455-3) was investigated in a GLP-compliant study (Ricau, 2013) performed in accordance with OECD Guideline 103 (Boiling point/boiling range) and EU Method A.2 (Boiling Temperature). The mean boiling point of the analogue substance was 280.5 ± 0.5°C. By analogy, a boiling point of 280.5 ± 0.5°C was reported for the target substance 1-Propanaminium, N-(3-aminopropyl)-2-hydroxy-N,N-dimethyl-3-sulfo-, N-(C12-18(even numbered) acyl) derivs., hydroxides, inner salts (EC 939-457-4).
The alkyl C-chain distribution of the source substance EC 939-455-3 significantly overlaps with the one of the target substance EC 939-457-7, the C12-alkyl derivative being the major constituent in both chemicals. The structural differences in side C-chains is not expected to lead to significant differences on phys-chem properties.
Key value for chemical safety assessment
- Boiling point at 101 325 Pa:
- 280.5 °C
Additional information
The boiling point of the structural analogue substance (= source substance EC 939-455-3) was investigated in a GLP-compliant study (Ricau, 2013) performed in accordance with standard methods, without deviations. The study is considered as reliable (Klimisch 1) and was selected as key study for the endpoint of the target substance EC 939-457-4.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.